• HOME
  • TRI SYSTEM Performance

TRI SYSTEM Performance

TRI SYSTEM Performance

TRI SYSTEM Performance

Test Conditions

We assure the product quality under the complete test conditions as follows.

Measuring Time
  • Initial Trial
  • After isothermal-isohumidity test
  • After thermal shock test
Isothermal-isohumidity test conditions
  • Temperature : 80℃
  • Humidity : 95%
  • Time : 200hours
Thermal Shock Test Conditions
  • Temperature 1 : 30 minutes at 80℃
  • Temperature 2 : 30 minutes at -40℃
  • Cycle : 150

Measuring shielding・waterproof ? a helium leak test

a helium leak test By using water molecule ,which is smaller than helium gas ,we measure its ability of high shielding capability・waterproof.
We check if there is any leak or not by high shielding capability experimet equipment.

Aluminums and PPS resins

We implement a helium leak test at each status.

Aluminums and PPS

Copper and PPS resin

We implement a helium leak test at each status.

Copper and PPS

result of helium leak test

Measuring Cementing Strength - Cementing Tensile Force Test

Cementing Tensile Force Test After cementing a resin with a metal formed a cementing film by insert-molding, we measure cementing strength by using a precision load measuring instrument.

Aluminums and PPS resins

Aluminums and PPS resins We implement a tensile force test by using a test specimen cemented an aluminum and a PPS resin at each status.

Copper and PPS resin

Copper and PPS resin We implement a tensile force test by using a test specimen cemented a Copper and a PPS resin at each status.

Result for test

Internal joining technology of metal and resin

Item Tensil Strength He leakage test High-temp&hum Thermal shock Remarks
Copper(Cu) 25~35Mpa OK 25Mpa~ 25Mpa~ Mass production
step
Aluminum(AL) 35~45Mpa OK 25Mpa~ 25Mpa~
Stainless(SUS) 30~40Mpa OK 25Mpa~ 25Mpa~ Completed
Development
Titanium(Ti) 30~40Mpa OK 25Mpa~ 25Mpa~
Iron(Fe) 30~40Mpa OK 25Mpa~ 25Mpa~
Magnesium(Mg) 30~40Mpa OK 25Mpa~ 25Mpa~
Zinc(Zn) 30~40Mpa OK 25Mpa~ 25Mpa~ Mass production
technology
Tin(Sn) 30~40Mpa OK 25Mpa~ 25Mpa~
Nickel(Ni) 20~25Mpa - - - In development

Applicable resin to TRI System※Used Material:AI

classi cation PBT PPS PA PPA TPE TPU PCT PEEK PP
Bonding
properties
  • What is TRI SYSTEM
  • Manufacturing Process of TRI SYSTEM
  • Applicable Technology of TRI SYSTEM
  • Main Facilities
 of TRI SYSTEM

to TOP